Example
:POWer:T2 0.200
Sets the T2 timer time to 200ms.
Query example
:POWer:T2?
>0.200
Returns the T2 timer time as 200ms.
:POWer:FREQuency
Set
Query
Description
Sets the CP dynamic mode switching frequency.
This command along with the “:POWer:Duty”
command is used when the dynamic time setting
is set to “Freq./Duty”.
This command is only applicable for dynamic
mode.
Syntax
:POWer:FREQuency {<NRf> | MINimum | MAXimum}
Query Syntax
:POWer:FREQuency?
Related
Commands
:POWer:DUTY
Parameter
<NRf>
Sets the switching
frequency in hertz.
MINIMUM or MIN
Minimum frequency
MAXIMUM or MAX
Maximum frequency
Return parameter
<NR2>
Returns the frequency in
hertz.
Example
:POWer:FREQuency 60
Sets the frequency to 60Hz.
Query example
:POWer:FREQuency?
>60
Returns the switching frequency (60Hz).