COMMNAND OVERVIEW
57
Query example
:STEP:CCH?
> CCH:0.002
Returns the step resolution (0.002A).
[:CONFigure]:STEP:CCM
Set
Query
Description
Configures the step resolution for CC medium
Range. Note: The step resolution setting will be
automatically rounded to the closest multiple of
the base resolution.
Syntax
[:CONFigure]:STEP:CCM {<NRf>[ A ] | MINimum |
MAXimum }
Query Syntax
[:CONFigure]:STEP:CCM?
Parameter
<NRf>[ A ]
Step resolution.
MINIMUM or MIN
Minimum step resolution
MAXIMUM or MAX
Maximum step resolution
Return parameter
<ASCII string>
Returns the range and the
step resolution.
Example
:STEP:CCM 0.0002A
Sets the step resolution to 0.0002A.
Query example
:STEP:CCM?
>CCM:0.0002
Returns the step resolution (0.0002A).
[:CONFigure]:STEP:CCL
Set
Query
Description
Configures the step resolution for CC low Range.
Note: The step resolution setting will be
automatically rounded to the closest multiple of
the base resolution.
Syntax
[:CONFigure]:STEP:CCL {<NRf>[ A ] | MINimum |
MAXimum }
Query Syntax
[:CONFigure]:STEP:CCL?
Zobrazit stránku 58