Gw-instek GOM-802 Programming Manual Uživatelský manuál Strana 16

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 27
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 15
DC MILLI-OHM METER
PROGRAMMER MANUAL
30
Examples:
:CONFigure:TCOMpensate:TEMPerature 20 sets require temperature to
20.0.
:CONFigure: TCOMpensate:TEMPerature? return “+2.0000E+1” to
indicate the 20.0.
The setting value and return values is in unit.
:CONFigure:SPEed
Function:
Set or query speed mode on or off.
Syntax:
:CONFigure:SPEed <Boolean>
<Boolean> can be o (off) or 1 (on).
:CONFigure:SPEed?
Return:
0/1
Examples:
:CONFigure:SPEed 1 sets speed mode, the conversation rate is 30
times/second.
:CONFigure:SPEed? return “1” to indicate the conversation rate is 30
times/second.
DC MILLI-OHM METER
PROGRAMMER MANUAL
31
:CONFigure:SCAN:STATe
Function:
Set or query scan mode on or off.
Syntax:
:CONFigure:SCAN:STATe <Boolean>
<Boolean> can be 0 (off) or 1 (on).
:CONFigure:SCAN:STATe?
Return:
0/1
Examples:
:CONFigure: SCAN:STATe 1 sets the scan mode on.
:CONFigure:SCAN:STATe? return “1” to indicate that the scan mode is
on.
:CONFigure:SCAN:CHANnel
Function:
Set or query the channel for scan.
Syntax:
:CONFigure:SCAN:CHANnel <NR1>
<NR1> is in the range from 0 to 1 .
:CONFigure:SCAN:CHANnel?
Return:
0/1
Zobrazit stránku 15