Gw-instek GDS-1000 Series Programming Manual Uživatelský manuál

Procházejte online nebo si stáhněte Uživatelský manuál pro Zařízení Gw-instek GDS-1000 Series Programming Manual. GW Instek GDS-1000 Series Programming Manual User Manual Uživatelská příručka

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 29
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 0
Digital Storage Oscilloscope
GDS-1000 Series
PROGRAMMING MANUAL
GW INSTEK PART NO.
ISO-9001 CERTIFIED MANUFACTURER
October 2007 edition
This manual contains proprietary information which is protected by
copyright. All rights are reserved. No part of this manual may be
photocopied, reproduced or translated to another language without
prior written consent of Good Will Corporation.
The information in this manual was correct at the time of printing.
However, Good Will continues to improve products and reserves the
right to change specifications, equipment, and maintenance
procedures at any time without notice.
Windows is a registered trademark of Microsoft Corporation in the United States and other countries.
Good Will Instrument Co., Ltd.
No. 7-1, Jhongsing Rd., Tucheng City, Taipei County 236, Taiwan.
Zobrazit stránku 0
1 2 3 4 5 6 ... 28 29

Shrnutí obsahu

Strany 1 - Digital Storage Oscilloscope

Digital Storage Oscilloscope GDS-1000 Series PROGRAMMING MANUAL GW INSTEK PART NO. ISO-9001 CERTIFIED MANUFACTURER October 2007 edition This

Strany 2 - INTERFACE OVERVIEW

COMMAND DETAILS 19 8BChannel / Math Command :CHANnel<X>:BWLimit... 206H19:CHANnel<X>:COUPl

Strany 3 - COMMAND OVERVIEW

COMMAND DETAILS 21 :channel<X>:invert <Boolean> :channel<X>:invert? :chan<X>:inv <Boolean> :chan<X>:inv? Param

Strany 4

COMMAND DETAILS 23 31B:CHANnel<X>:SCALe SetQuery Description Sets or returns the vertical scale. The scale depends on the probe attenuation

Strany 5

COMMAND DETAILS 25 33B:CURSor:Y<X>Position SetQuery Description Selects or returns the vertical (Y axis) cursor position. Same as: Cursor k

Strany 6 - COMMAND DETAILS

COMMAND DETAILS 27 36B:CURSor:SOURce SetQuery Description Selects or returns the cursor source channel. Same as: Cursor key →F1 (Source) Syntax &

Strany 7 - System command

COMMAND DETAILS 29 Parameter <NR1> Display contrast –10 ~ 10 Lowest (–10) to the Highest (+10) Example :display:contrast 0 Sets the displa

Strany 8 - Acquisition Command

COMMAND DETAILS 31 11BMeasure command :MEASure:FALL... 224H31:MEASure:FOVShoot ...

Strany 9 - Autoset Command

COMMAND DETAILS 33 Description Returns the frequency value. Same as: Measure key → F1~F5 → F3 (Frequency) Syntax < Long > < Short > :

Strany 10 - Channel / Math Command

COMMAND DETAILS 35 50B:MEASure:RISe Query Description Returns the first pulse rising edge timing. Same as: Measure key → F1~F5 → F3 (RiseTime) Syn

Strany 11 - :CHANnel<X>:PROBe

COMMAND DETAILS 37 Example :measure:source 1 :measure:vamplitude? Selects Channel 1, and then measures the rise Voltage amplitude. 55B:MEASure:VAVe

Strany 12 - Cursor Command

TABLE OF CONTENTS 3 Table of Contents INTERFACE OVERVIEW ... 4 Rear Panel Overview ...

Strany 13 - :CURSor:<X>DISplay

COMMAND DETAILS 39 Note Before using this command, select the measurement channel. See the example below. Example :measure:source 1 :measure:vmin?

Strany 14 - Display Command

COMMAND DETAILS 41 1 ~ 15 W1 ~ W15 <NR1> Reference waveform 1, 2 RefA, RefB Example :memory1:recall:waveform 1 Recalls a waveform from

Strany 15 - :REFResh

COMMAND DETAILS 43 Example :ref1:display 1 Turns on the reference waveform A 68B:REF<X>:LOCate SetQuery Description Moves or returns the po

Strany 16 - Measure command

COMMAND DETAILS 45 13BTime (Horizontal) command :TIMebase:DELay... 253H45:TIMebase:SCALe...

Strany 17 - :MEASure:PWIDth

COMMAND DETAILS 47 Description Sets or returns the width of the zoomed window. Same as: Horizontal menu key → F2 (Window) → Time/div knob Syntax &l

Strany 18 - :MEASure:VAMPlitude

COMMAND DETAILS 49 Description Starts waiting for a trigger condition. Same as: Run key Syntax :run 78B:SINGle Set Description Selects the single

Strany 19 - :MEASure:VMIN

COMMAND DETAILS 51 Description Selects or returns the trigger mode. Same as: Trigger key → F5 Syntax < Long > < Short > :trigger:mode

Strany 20 - Save/Recall Command

COMMAND DETAILS 53 Example :trigger:type 2 :trigger:pulse:time 1 Selects the pulse trigger and sets the trigger time as 1sec 88B:TRIGger:REJect Se

Strany 21 - :REF<X>:DISPlay

COMMAND DETAILS 55 1 Video Example :trigger:type 0 Selects the edge trigger type 92B:TRIGger:VIDeo:FIELd SetQuery Description Selects the tri

Strany 22 - :REF<X>:SAVe

COMMAND DETAILS 57 :trigger:video:type <NR1> :trigger:video:type? :trig:vid:typ <NR1> :trig:vid:typ? Parameter <NR1> Type <NR

Strany 23 - Time (Horizontal) command

INTERFACE OVERVIEW 5 Configuring the USB Interface PC side connector Type A, host USB connection GDS-1000 side connector Type B, slave Speed 1.1/2

Strany 24 - Trigger command

COMMAND OVERVIEW 7 List of Command in Functional Order System *IDN... 13*L

Strany 25

COMMAND OVERVIEW 9 Time (Horizontal) :TIMebase:DELay... 45:TIMebase:SCALe...

Strany 26 - :TRIGger:PULSe:TIMe

COMMAND OVERVIEW 11 Command Page Command Page T :TRIGger:NREJ 166H51 :TIMebase:DELay 167H45 :TRIGger:PULSe:MODe 168H52 :TIMebase:SCALe 169H

Strany 27 - :TRIGger:TYPe

COMMAND DETAILS 13 5BSystem command *IDN... 198H13*LRN ...

Strany 28 - :TRIGger:VIDeo:TYPe

COMMAND DETAILS 15 6BAcquisition Command :ACQuire:AVERage..... 203H15:ACQuire:MODe ...

Strany 29

COMMAND DETAILS 17 Data size Indicates the data size. The data size is always 8008 (4000 points per channel). Time interval Indicates the time