94
:TIMebase:MODe
Description
Sets or queries the time base mode. The time base
mode determines the display view window on the
scope.
Syntax
:TIMebase:MODe {MAIN | WINDow | XY | ?}
Parameter
MAIN
Sets the time base mode to the main
screen.
WINDow
Sets the time base mode to the zoom
window.
XY
Sets the time base mode to the XY
display.
Return parameter
Returns the time base mode (MAIN, WINDOW,
XY)
Example
:TIMebase:MODe MAIN
Sets the time base mode to the main mode.
:TIMebase:WINDow:POSition
Description
Sets or queries the zoom horizontal position.
Syntax
:TIMebase:WINDow:POSition {<NRf> | ?}
Related
commands
:TIMebase:MODe
Parameter
<NRf>
Horizontal position for zoom window
Return parameter
<NR3>
Returns the zoom horizontal position.
Example
:TIMebase:WINDow:POSition 2.0E-2
Sets the zoom horizontal position as 20ms.
Set
Query
Set
Query