Gw-instek GDS-200 Series Programming Manual Uživatelský manuál Strana 60

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 139
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 59
GDS-200 & GDS-300 Programming Manual
60
:MEASure:PK2PK
Description
Returns the peak-to-peak amplitude (difference
between maximum and minimum amplitude).
Syntax
:MEASure:PK2Pk?
Related
Commands
:MEASure:SOURce<X>
Return parameter
<NR3>
Returns the voltage or current peak to
peak measurement.
Chan Off
Indicates the source channel is not
activated.
Note
Before using this command, select the
measurement channel. See the example below.
Example
:MEASure:SOURce1 CH1
:MEASure:PK2Pk?
2.04E-1
Selects Channel 1, and then measures the peak-to-
peak amplitude.
:MEASure:MAX
Description
Returns the maximum amplitude.
Syntax
:MEASure:MAX?
Related
Commands
:MEASure:SOURce<X>
Return parameter
<NR3>
Returns the maximum amplitude.
Chan Off
Indicates the source channel is not
activated.
Note
Before using this command, select the
measurement channel. See the example below.
Query
Query