GDS-200 & GDS-300 Programming Manual
76
Related
Commands
:MEASure:SOURce<X>
Return parameter
<NR3>
Returns the delay.
Chan Off
Indicates the source channel is not
activated.
Note
Select the two source channels before entering this
command.
Example
:MEASure:SOURce1 CH1
:MEASure:SOURce2 CH2
:MEASure:FRFDelay?
3.43E-6
Select channel 1 and 2 as source1/2, and then
measure FRF.
:MEASure:FFRDelay
Description
Returns the delay between the first falling edge of
source1 and the first rising edge of source2.
Syntax
:MEASure:FRRDelay?
Related
Commands
:MEASure:SOURce<X>
Return parameter
<NR3>
Returns the delay.
Chan Off
Indicates the source channel is not
activated.
Note
Select the two source channels before entering this
command.
Example
:MEASure:SOURce1 CH1
:MEASure:SOURce2 CH2
:MEASure:FRRDelay?
-8.56E-6
Select channel 1 and 2 as delay source1/2, and
then measure FFR.