COMMAND DETAILS
63
:MEASure:RISe
Query
Description
Returns the first pulse rise time.
Syntax
:MEASure:RISe{?}
Return parameter
Returns the rise time as <NR3>
Note
Before using this command, select the
measurement channel. See the example below.
Example
:MEASure:SOURce1 CH 1
:MEASure:RISe?
8.5E-6
Selects Channel 1, and then measures the rise time.
:MEASure:ROVShoot
Query
Description
Returns the rising overshoot over entire waveform
in percentage.
Syntax
:MEASure:ROVShoot{?}
Return parameter
Returns the overshoot as <NR3>
Note
Before using this command, select the
measurement channel. See the example below.
Example
:MEASure:SOURce1 CH 1
:MEASure:ROVShoot?
5.00E+00
Selects Channel 1, and then measures the rise
overshoot.
:MEASure:RPReshoot
Query
Description
Returns rising preshoot over entire waveform in
percentage.
Syntax
:MEASure:RPReshoot{?}
Zobrazit stránku 62