Gw-instek GDS-1000-U Series Programming Manual Uživatelský manuál Strana 34

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 70
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 33
GDS-1000-U Programming Manual
34
Example
:measure:source 1
:measure:pwidth?
Selects Channel 1, and
then measures the
positive pulse width.
:MEASure:RISe
Query
Description
Returns the first pulse rising edge timing.
Same as: Measure key F1~F5 F3 (RiseTime)
Syntax
< Long >
< Short >
:measure:rise?
:meas:ris?
Returns
<NR3>
Note
Before using this command, select the
measurement channel. See the example below.
Example
:measure:source 1
:measure:rise?
Selects Channel 1, and
then measures the
rising edge timing.
:MEASure:ROVShoot
Query
Description
Returns rise overshoot amplitude in percentage.
Same as: Measure key F1~F5 F3 (ROVShoot)
Syntax
< Long >
< Short >
:measure:rovshoot?
:meas:rovs?
Returns
<NR2> with % sign
Note
Before using this command, select the
measurement channel. See the example below.
Example
:measure:source 1
:measure:rovshoot?
Selects Channel 1, and
then measures the rise
overshoot.
Zobrazit stránku 33
1 2 ... 29 30 31 32 33 34 35 36 37 38 39 ... 69 70

Komentáře k této Příručce

Žádné komentáře